Mercury
1500S
DDiiggiittaall OOuuttppuutt EEnnccooddeerr SSyysstteemmss
Installation Manual
and Reference Guide
Manual No. IM-M1500S Rev F
Vista de pagina 0
1 2 3 4 5 6 ... 18 19

Indice de contenidos

Pagina 1 - Installation Manual

Mercury™1500S DDiiggiittaall OOuuttppuutt EEnnccooddeerr SSyysstteemmssInstallation Manual and Reference GuideManual No. IM-M1500S Rev F

Pagina 2 - PPrreeccaauuttiioonnss

Page 8Attach your hub/scaleassembly to the rotarydevice. Refer to theinterface drawing. Thereflective surface of thescale must face the sensor.13Be su

Pagina 3 - ENCODER TROUBLESHOOTING

Page 95Proper sensor alignment may require minor adjustments to the sensor position withrespect to the scale. This can be performed easily using the S

Pagina 4 - Mercury 1500S Encoder System

Attach your hub/scaleassembly to the rotarydevice. Refer to theinterface drawing. Thereflective surface of thescale must face the sensor.1Page 103Be s

Pagina 5

Page 114INDEX TRACK ALIGNMENTThe M1500S must be aligned for both the mainand index tracks. When properly aligned, thesensor will produce an index wind

Pagina 6

Installation Reference GuidePage 12MicroE SystemsL0.2L0.6L0.2LBenching pinsPositioning the ScaleNote: Before beginning mounting procedure, use talc-f

Pagina 7

Page 13Grounding of M1500SFor Mercury 1500S encoder systems to operate reliably, it is essential that the sensor and cable shield are grounded proper

Pagina 8

Page 14Mercury 1500SSignal Twisted PairA+ Pair 1A-B+ Pair 2B-Index+ Pair 3Index-+5V Pair 4GNDCustomer Interface Cable RequirementsCustomer ca

Pagina 9

Page 15SINE+/COSINE+Analog signal with nominal peak to peak amplitude of 0.8V. The output signal has a source impedance of 1KΩ. This signal is only

Pagina 10 - Installation Instructions

TroubleshootingProblemThe Power/Calibration indicator will not come on.Solution• Make sure the M1500S 15-pin D connector is fully seated and connected

Pagina 11

World Headquarters: 125 Middlesex Turnpike • Bedford • MA 01730 USAwww.microesys.com • [email protected] • T. [781] 266-5700 • F. [781] 266-

Pagina 12

IInnttrroodduuccttiioonnMicroE Systems was founded to advance encoder technology toa level never before achieved. Our objective was to design encoders

Pagina 13

Page 1TTaabbllee OOff CCoonntteennttssSYSTEM ILLUSTRATION PAGEEncoder with Linear scale 2Encoder with Rotary scale 3INSTALLATION INSTRUCTIONSUsing S

Pagina 14 - Installation Reference Guide

Page 2Mercury 1500S Encoder System with Linear scaleSSyysstteemm VViieewwShown with linear scaleSensor(shown attached on a linear slide base with mou

Pagina 15 - Grounding of M1500S

Page 3Mercury 1500S Encoder System with Rotary scaleSensorGlass scale Rotary scaleDouble shielded cableIndex markTop reflective rotary scalemain track

Pagina 16 - Shield Termination:

Page 412Attach the scale to the base slide. Reference the preferreddatum on the interface drawing for either end or centerindex orientation. Depending

Pagina 17 - Output Signal Description

Page 5Proper sensor alignment may require minor adjustments to the sensor position withrespect to the scale. This can be performed easily using the op

Pagina 18 - Cleaning Scales

Page 612Attach the scale to the baseslide. Reference the preferreddatum on the interface drawingfor either end or center indexorientation. Depending o

Pagina 19 - Contact MicroE Systems

Page 74INDEX TRACK ALIGNMENTThe M1500S must be aligned for both the main andindex tracks. When properly aligned, the sensor willproduce an index windo