Microe Mercury II 6000 Manual de usuario Pagina 36

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 73
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 35
Appendix
IM-Mercury_II_6000 Series Rev. 1 Page 35 ©2014 MicroE Systems
Limit settings: The limit state (Active High: status bit = 1 when limits is active, or Active
Low: status bit = 0 when limit is active) and limit polarity (normal, or left and right limits
reversed) can be changed. The limits may also be enabled or disabled.
Performance Specifications
Resolution: 5µm to approximately 1.22nm
Maximum travel before position counter rollover, with fringe count bits set to 21: 41.94304
meters
Maximum speed: 10m/s
Maximum cable length: 10m
7.6 Index Speed Considerations
MII6000
Maximum Speed for MII6000 Index after Power-up (MII6800, MII6700 and MII6500 Models):
Each time an MII6800, MII6700, or MII6500 encoder is powered up, the first pass over the index
mark must occur at a speed 1m/s. Once the index is initially detected, the index will function at
all speeds (up to 10m/s) until the next power cycle.
Vista de pagina 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 72 73

Comentarios a estos manuales

Sin comentarios